PUMP STATION INSTALLATION

Project Details

This project we conducted High Voltage and Low Voltage electrical installation works required
to establish a new High Voltage Feeder line which connected from existing High Voltage
infrastructure to a new MCC panel and pump station. The installation works typically
entailed the following:

a. Installation of HV aerials, switchgear, transformer and associated support systems to poles;
b. Installation of an earth grid system;
c. Installation of switchboard MCC-51;
d. Installation of HV and LV cabling and associated cable support systems
e. Installation of level transmitter and cabling of instrumentation.
f. The earthing Matt underneath the MCC board was bonding to the main earthing conductor using thermoweld techniques

Applicable Codes and Standards

All equipment designed, manufactured, tested and installed was in accordance with the most
current version of relevant Australian Standards, Codes and Regulations, except where specifically
modified by this specification.
Where Australian Standards, Codes and Regulations do not exist, those of International Standards
Organisation (ISO) or other standards shall apply.
Applicable codes and standards include but are not limited to including:
a) AS/NZS 1755 – Conveyors—Safety requirements
b) AS/NZS 1025 – High Voltage A.C Switchgear and Control Gear;
c) AS/NZS 1345 – Rules for the identification of Piping, Conduits and Ducts;
d) AS/NZS 1680 – Lighting;
e) AS/NZS 1930 – Circuit Breakers for Distribution Circuits;
f) AS/NZS 1939 – Degrees of Protection Provided by Enclosures for Electrical Equipment;
g) AS/NZS 2053-1984 – Non-metallic conduits and fittings;
h) AS/NZS 2184 – Moulded Case Circuit Breakers;
i) AS/NZS 2380.1 – Electrical Equipment for Explosive Atmospheres – Explosion Protection Techniques – General Requirements;
j) AS/NZS 2293 – Emergency Lighting;
k) AS/NZS 2381 (All parts) – Electrical equipment for explosive gas atmospheres;
l) AS/NZS 2381 series – Electrical equipment for explosive atmospheres1;
m) AS/NZS 3000 – Wiring Rules and all Normative and Informative documents reference therein;
n) AS/NZS 3008 – Cables for Alternating Current Up to and including 0.6/1kV;
o) AS/NZS 3017:2007 Electrical installations—Verification guidelines;
p) AS/NZS 3190 – Current Operated Earth Leakage Devices;
q) AS/NZS 3439 – Low Voltage Switchgear and Control Assemblies;
r) AS/NZS 60079 series – Explosive atmospheres;
s) AS/NZS 61000.3.6 Electromagnetic compatibility (EMC) : Part 3.6: Limits—Assessment of emission limits for distorting loads in MV and HV power systems;
t) AS/NZS 61241 series – Electrical apparatus for use in the presence of combustible dust;
u) HB13 – 2007 – Handbook Electrical Equipment for Hazardous Areas;
v) NFPA70E – Electrical Work Safety Standard;
w) IEEE 1584 – IEEE Guide for Performing Arc Flash Hazard Calculations .